DRAIN MASTER B
- Air leakage is so little that economic effect is excellent, and withdrawal of early investment expense is fast.
- Outlet diameter is large (inside diameter 12) that there is no block phenomenon, and it is safety because there is restoration ability when converts to emergency mode.
- Control is easy because all operations are automated.
- It operates normally in atmospheric pressure state.
- Emergency manual operation is available (needs not by-pass line).
- Body: SCS13A. Ball: Durability is good and strong against corrosion by using SUS304 quality of the material.
- Switching time of electric actuation ball valve is short that operate ball valve is opened perfectly at operation (scale discharge is excellent).
DRAIN MASTER B Operation Principle
1) Condensate that is flowed through lead-in line 1 is gathered to housing 2.
2) If condensate water level rises in housing, it is sensed in the high level sensor 3.
3) Electric actuation ball valve 5 is run if transmit open signal in main board and condensate is discharged through outlet 6.
4) If level of condensate water inside housing comes down 4, it is sensed in the sensor bottom dead center, and electric actuation 5 ball valve that received close signal is closed.
Electrostatic capacity sensor
Any condensate from compression process can be sensed correctly and discharged.
There are little loss of compressed air
Uses of two sensors (high level, low level) protects energy loss by air loss discharging condensate selectively.
Automatic discharge function
In case of condensate is not discharged while 2 minutes by scale etc., it makes recognition to user through alarm signal and it is converted to automatic restoration function and it activates electric motion ball valve by 5 seconds every 3 minutes.
It is returned by normally mode if discharge is achieved normally.
Durability (Hard-Anodizing)
Housing coated rigid coating applying for aircraft, semiconductor equipment etc. of industrial equipment required durability is excellent nature of rust proof durability and abrasion etc. so that life of housing is semi-permanent.
Various model, beautiful design
Extended user's selection by subdividing into three models according to quantity of condensate, and housing is processed by anodizing method and die casting mold that has beautiful design.
Convenience of install and maintenance
- Put lead-in line more than 3 lines so that power connection is easy, and piping is convenient.
- Housing internal pollutant cleaning is simple.
- The built-in strainer can prevent the breakage of valve by the sludge and phenomenon to be blocked.
Technical Specification
DRAIN MASTER B
|
Model
|
DM-150B
|
DM-500B
|
DM-1500B
|
DM-2500B
|
DM-5000B
|
Compressor Capacity (m3/min)
|
150
|
500
|
1500
|
2500
|
5000
|
Dryer Capacity (m3/min)
|
300
|
1000
|
3000
|
-
|
-
|
Filter Capacity (m3/min)
|
1500
|
5000
|
-
|
-
|
-
|
Operating Pressure (bar)
|
0.8 – 16
|
Voltage AC (V)
|
Free Voltage 90 – 260, 24/48 V AC, 24/48 V DC
|
Application
|
Oil Injection, Oil Free
|
Temperature (0C)
|
+ 1 – 80
|
Inlet (inch)
|
¾”x3
|
¾”x2, 1”x1
|
FL 1”
|
FL 2”
|
Outlet (inch)
|
½”x1
|
½”x1
|
½”x2
|
Housing Material
|
Aluminium, Hardcoated
|
Stainless Steel
|
Weight (kg)
|
3.90
|
6.00
|
7.50
|
20.50
|
29.00
|
Dimension (WxLxH mm)
|
220x110x230
|
260x160x240
|
330x160x245
|
522x216x350
|
587x267x400
|
* Must attach automatic thermostat (Option: Heater/110.220V/125W) in freezing area.
* Else above models are custom-built.
* Above specification can be changed without advance notice for improvement of performance (2009.10)